Readme F-Editor

Readme F-Editor

 

 

Version

Date

Modifications

1.04

24.02.11

  • Adaption to BL-NET from version 2.02. Older data (version 1.43) will be converted automatically on opening and can be used after saving further on only with BL-NET version ≥ 2.02.

1.03

1.12.10

  • CAN I/O Module: Addition of sensor „RAS PT“ on inputs and modification of factory setting on analog inputs from KTY to PT1000.
  • BL-NET: Configuration dialog for CAN data logging enlarged, as in case of higher type size (120DPI) a part of control elements have been missed.

1.02

04.10.10

  • Several bug-fix’s in parameter documentation of CAN I/O Module:
  1. Functions -> Mixer control -> Input variables -> Enable mixer -> on “Source: Network” the numbering for digital input has been displayed wrong. On control temperature the designation “Input” was missed on source indication.
  2. Network -> Input variables-> digital input variables -> the designation was displayed with an unnecessary number.
  3. Analog output -> wrong formatting of scaling on mode 0-10V.
  4. Network outputs -> transmission conditions -> digital output 1...8 -> On Change -> yes/no have been changed.
  • Bug-fix on CAN I/O Module: “Average value” on inputs has been saved right, but not reloaded (always loaded as 0.0 sec.).
  • Modification on CAN I/O Module: On measuring variable “Wind speed” the default value for “Quotient” is modified to 0.05Hz.
  • Bug-fix on CAN I/O Module: On input 2 of Module 44 it was possible to select the type “Pulse”, although it is not possible at the device.
  • Modification on BL-NET: On “Event for SMS (GSM settings  ->  inputs, outputs) the value will be backgrounded grey resp. not be displayed in text documentation if event “-“ is selected.
  • Adaption to CAN Monitor 2.06 (sensor correction for dew point in menu “inputs” added.).
  • Revision of selection of network inputs and outputs (BL-NET, CAN-BC) and addition of overview.

1.01

02.02.10

  • Additional languages (English, French, Italian and Spanish) inserted.
  • Bug-fix on initialization of storage criterion (BL-NET): Time interval could be set to “0 min : 0 sec”.
  • Bug-fix on CAN I/O Module: Sensor type of inputs did not change automatically on switch-over to measuring variable temperature.
  • Modification of wrong designation in text files (0.8 beta).
  • Adaption to CAN I/O Module version A2.03 (T.Abs.NOM, T.Ev.THRES and T.CtrlNOM changed from maximal 99°C to 200°C.).

1.00

01.12.09

  • First version (German only)
 