T.A.P.P.S. Version
|
Operating system UVR1611
|
Date
|
Modifications, innovations and Incompatibilities
|
|
1.28
|
from A3.24 resp. A2.28
|
23.02.2011
|
New:
- Support of User Interlock MENU for UVR1611 from version A3.24
Modifications:
- Determining the system requirements of function data the minimum requirement to the operation system of UVR1611 from version A3.20 will be treated sophisticated. I.e., a higher version than A3.20 will only be demanded, if newer functionality is used. Until now TAPPS checked only if version 2.28 is sufficient. If not, always the highest operating system A3.xx of UVR1611 has been demanded.
|
|
1.27
|
from A3.20 resp. A2.28
|
22.11.2010
|
New:
- Supports RAS PT (room sensor based on PT1000) for UVR1611 from version A3.20.
- Inputs: Change of default sensor type from KTY10 to PT1000.
- Inputs: Change of default value for quotient of wind speed from 0.01HZ to 0.05Hz (corresponding to TA wind sensor).
- Counter: In case of actual count of operating hours it is possible now to input minutes for service reasons too. Since version A3.18 of UVR1611 minutes of actual count are displayed besides hours.
- Counter: The actual count of operating hours resp. pulses is also indicated in parameter documentation.
- Heat quantity counter: The actual count as well as the calibration parameters is indicated in parameter documentation.
Modifications:
- The value of the variable „AutoRefreshTime“ is indicated now without quotation marks. The variety up to now operated without problems too, but not so perfect.
- The html-file generated from TAPPS for online diagram will be generated without previous Java-script function „set_dimenson_para()“, as it is not necessary for functionality.
- Bug-fix Logic function: The number of input variables has only been actualized if at least one input variable has been linked. I.e., after deleting of all input variables the number was not reset to “1” but remained unchanged.
- Bug-fix Parameter documentation: Selecting “Filter unused outputs” the analog output A16 has not been logged in parameter documentation.
- Bug-fix Parameter documentation: On function Boiler cascade the input variable “Enable third boiler stage” without link has been logged as “User unused” in parameter documentation, also in case of 3 boilers.
- Bug-fix Function overview: Display error in user interface editor on mixer outputs. If the second mixer output was previously defined as switching output, the old designation has been displayed.
|
|
1.26
|
from A3.18 resp. A2.28
|
03.02.10
|
New:
- The html-file for Online diagram of BL-NET will be generated in new format. This variety allows among others an automatical actualization of measuring values without renewing the graphics. This new format of Online diagram requires BL-NET from version 1.40!
- Enables optional input of calibration values of Heat quantity counter in new format (for UVR1611 from version A3.18) or in previous format (for older versions).
- Supports the use of Heat quantity counter as energy counter (electrical performance) for UVR1611 from version A3.18. When input variables flow and return temperature are defined <user/unused>, therefore without link, Heat quantity counter is in mode “Energy counter”.
Modifications:
- Bug-fix: Background color black was assumed incorrectly to html-file in case of placeholder in Online diagrams.
- Bug-fix: The minimum requirement of UVR1611 for DL bus is corrected to serial number 13286. Up to now serial number 8006 was displayed wrongly as minimum requirement.
- Bug-fix on wrong English translations: Flow (previous wrong: pre-run) and flow rate (previous wrong: flow).
|
|
1.25
|
from A3.17 resp. A2.28
|
08.09.09
|
New:
- Support of CAN data logging settings of UVR1611 from version A3.17.
Modifications:
- Bug-fix from TAPPS 1.24: Evaluation of drawing could lead to crash of para1611.
- On determination the system requirements for function data the identification number of the function (FuncID) will be observed, as UVR1611 at version 2.28 supports only FuncID’s in range [0..39].
- Bug-fix: If up to now more than 40 function have been used for short time in TAPPS version 1.23 and some have been deleted afterwards, the requirements for version A2.28 (max. 40 functions) have been fulfilled again according to TAPPS, but a FuncID>39 lead to a UVR1611 with operating system A2.28 but with wrong links to the function.
- Bug-fix of parameter documentation: On PID control the nominal value of differential control in case of values >25°C, wrong values have been logged in text file.
- Bug-fix of TAPPS1.23: This bug caused after changing of user-defined names on parameterizing of in- and outputs in case of a new function in the drawing, to which not yet have been assigned parameters, that the name and some input variables have been changed to wrong display in the drawing.
- Bug-fix: The drawing objects in library “Functions” have been revised, so that the frame has become the lowest drawing element in the z-level. Up to now some texts e.g., function type and names have been invisible if the function box has been filled with color.
- Changed default value in CAN network: Enable: ON (up to now: OFF).
|
|
1.24
|
from A3.15 resp. A2.28
|
15.05.09
|
New:
- The process „Evaluation of drawing“ has been optimized temporally. On evaluation temporary files will be loaded to RAM for quick reading accesses.
- Now the memory requirement of functions will also be checked during parameterizing of a function. So that the user will be pointed by advisory to a too large memory demand not only on <Export to translator> but even during parameterizing of new functions.
- The number of used functions, their memory requirement as well as the number of used messages will be displayed as informations in the error log of parameterizing window.
- On <Export to translator> it will be checked if several network input variables are defined for the same parameter (source, NWN=network node, NWO=network output), because it would not be processed correctly by the UVR1611.
Modifications:
- Bug-fix of TAPPS 1.23 on scaling of input for process variable „Flow rate“. Scaling of >1000 l/h has been reset during saving to 1000 l/h, whereby the necessary scaling of VFS2-40 (1.95V ... 1200 l/h) could not be set right.
- Bug-fix: In case of older drawings (TAPPS<1.23) resp. function data (UVR1611 <A3.00) the function types of function no. 41 to 44 are not parameterized as <unused> as for these versions only maximal 40 functions are possible. On TAPPS 1.23 following malfunction on programming based on older versions could happen:
- On “Arrange functions” more functions are displayed than really existing.
- On “Check system requirements” a too great number of used functions has been detected.
- On “Import from translator” incompatibilities of drawings and function data have been reported wrongly.
- Modified default values in functions:
- Analog function: Number of input variables after default changed to 1 (instead of 2)
- Modified default values in messages:
- Enable message: User/ON (instead user/OFF up to now)
|
|
1.23
|
from A3.10 resp. A2.28
|
13.02.09
|
New:
- Adaptions and Extensions for UVR1611 from version A2.26:
- Process variable “pressure” in inputs
- Function variable “pressure” on function Comparison.
- Adaptions and Extensions for UVR1611 from version A3.00:
- Potentiostat removed.
- Maximal number of functions extended from 40 to 44.
- Setting range of PID function increased from 150°C to 200°C.
- Second analog output (A16) – because of compatibility to older versions it is not possible to control the output A16 directly from functions Function control and Boiler cascade.
- Possibility of PWM on analog outputs
- user-defined names on functions
- Network inputs can read data from DL bus (Data link).
- For generating function data by TAPPS for the actual version of UVR1611 as well as for version A2.28 the system requirements of function data on <Export to translator> will be determined from the drawing. The minimal requirement (operating system, serial number) of UVR1611 will be displayed in compiler window.
- Generating the parameter documentation for the function data of the drawing the system informations (TAPPS version and minimal requirements of UVR1611) will be set onto the top of the text file.
Modifications:
- Bug-fix: If a note with more than 255 characters have been input on drawing features (file feature...), a memory area error lead among other things to overwriting the feature “keywords”. For notes it is possible to input maximal 1000 characters.
- The target path of text file for parameter documentation will only be saved if it will be set by user on “Select target...”. If no target path is set, the default path and name of the drawing (*.eng) will be used.
- If on parameterizing user-defined names have been modified, the names of all library elements, which exist in the drawing, will be checked and, if necessary, actualized.
- The input line for setting a new user-defined name is limited to maximal 12 characters. Up to now only on applying a too long name a corresponding error message was created.
- Modified default values in functions:
- Heating circuit control: Pre-defined time program: Mo – Su from 06:00 to 22:00 h.
- Analog function: Result if Enable = OFF: 0°C
- On library objects of network inputs and outputs the color of type names has been changed for better readability:
- Network input: text color: white, background color: black
- Network output: text color: white, background color: blue.
- On drawing symbols of network inputs the selected source (CAN / DL) will be displayed as additional information to the type name. For already existing network input symbols in the drawing from older TAPPS version (TAPPS < 1.20) this additional information will not be displayed.
|
|
1.22
|
from A2.22
|
14.05.08
|
New:
- The software is available in 5 languages (German, English, French, Italian and Spanish).
Modifications:
- After selection of parameterization of Signal transfer / adoption the actual signal identification will be displayed in input line of parameterization window. Up to now the input line was empty after selection of parameterization.
- Additional error messages on handling of parameterization (.par) added.
- Bug-fix on direct start of drawing (.eng) by double-clicks in Explorer. In this case the author (File? Features...) was reset. On regular opening of drawing (File? Open) the author was loaded correctly anyway.
|
|
1.21
|
ab A2.22
|
31.03.08
|
New:
- TAPPS is used as editor with the library „Online diagram“ for graphical creating the html-file for Online diagram of Bootloader BL-NET.
Modifications:
- Parameterizing of new unused inputs/outputs (e.g., “S0 unused”) as well as network inputs/outputs the first input/output will not be selected further on as default value, but the library object will be displayed as “unused”
|
|
1.20
|
ab A2.16
|
11.09.07
|
New:
- The software is available in several languages. Opening a drawing, which was created by a foreign-language version of TAPPS, the TA library objects of the logical diagram will be converted automatically to the actual language of TAPPS. The automatic translation is only possible for drawing objects, which come from a library of TAPPS from version 1.20. Older symbols cannot be translated and remain unchanged.
Drawings created with version 1.20 or higher are not downwards compatible; therefore they are not editable with older versions (< 1.20) of TAPPS.
- Improved check of logical links. Direct links of an input or a network variable with an output will be displayed as error now. Up to now such invalid links have been ignored from compiler without error message.
- Creating parameter documentation of external source files (*.dat) the memory requirement of used functions will be checked.
- Extension of library for hydraulic symbols with flow switch, volume flow sensor and position indicator.
- New TAPPS tutorial.
Modifications:
- Bug-fix of User interface editor. Inserting a parameter at first position in front of already existing parameters of a source it has been inserted at a wrong position.
|
|
1.19
|
from A2.16 B2.16
|
13.10.06
|
Modifications:
- Opening a drawing a corresponding error message is created if the corresponding parameter file (*.par) cannot be loaded.
|
|
1.18
|
from A2.15 B2.15
|
28.08.06
|
Modifications:
- Bug-fix on check of the memory requirement of parameters resp. variables of functions.
|
|
1.17
|
from A2.15 B2.15
|
28.07.06
|
New:
- Actual counts are adjustable in TAPPS in function Boiler cascade for service purposes.
- In case of too large parameter resp. memory requirement and corresponding warning resp. error message the number of bytes, which exceeds the maximal memory requirement, is indicated.
- In case of excess of the maximal possible number of functions resp. messages and corresponding error message the number of objects, which exceeds the maximal number, is indicated.
Modifications:
- Bug-fix on import of calibration values of Heat quantity counter (Calibration values have been adopted only partly.).
- Bug-fix on repeated load of the same library into TAPPS.
|
|
1.16
|
from A2.12 B2.12
|
09.05.06
|
Modifications:
- Bug-fix on parameter documentation.
- Parameters for drawing templates (*.evl) are saved as *.pvl files. Up to now the parameter have been saved as *.par like a drawing (*.eng). For compatibility to older drawings a corresponding *.par file will be loaded when opening a template, which has no corresponding *.pvl file.
- Closing a drawing a request „Save modifications?“ will be displayed now, if only parameters (e.g., of a function) and not the drawing itself have been modified.
- Calling of a parameter window an already opened parameter window will be closed automatically. Up to now only an error message, that parameterization is already in performance, has been displayed and the calling of the window has been cancelled.
|
|
1.15
|
from A2.08 B2.07
|
18.01.06
|
Modifications:
- Bug-fix of faulty display of relative year (e.g., in header and footer)
- Bug-fix on finishing TAPPS via file => Finishing under WinXP resp. Win2000 corrected.
- Bug-fix on parameter documentation of Function overview from an external source.
|
|
1.14
|
from A2.07 B2.07
|
15.11.05
|
New:
- Possibility to create a parameter documentation from a dat-file (external source)
- Possibility of parameter documentation for Function overview.
- Export filter for parameter documentation (e.g. filtering unused inputs/outputs)
- User defined welcome page can be assigned now to function data in TAPPS (export to translator).
- Possibility of parameter import (import from translator) from dat-file (under certain conditions).
Importing of parameters is only possible on condition that no more function resp. message has been added or removed and no link has been modified.
Modifications:
- Bug-fix on reversing of cancelling process of a grouped object in the drawing.
- Modified default parameter values for some functions (Warm water requirement, Cooling function, Load pump, Comparison, Circulation, PID control).
Incompatibilities:
- In case of older versions than A2.07 the Welcome page can only be loaded via operating system update.
|
|
1.13
|
from A2.00 B2.00
|
21.02.05
|
New:
- Calibration parameters of Heat quantity counter can be set in TAPPS.
- Actual counts of Heat quantity counter and Counter can be set in TAPPS for service purposes.
Modifications:
- Bug-fix on Printing (Infinite loop in case of some printers).
|
|
1.12
|
from A1.39 resp. A1.54 B1.01
|
15.09.04
|
New:
- Export of parameters to a txt-file.
|
|
1.11
|
from A1.39 resp. A1.54 B1.01
|
14.05.04
|
Modifications:
- Library object „Warm water requirement“: Additional input variable <external switch> (old drawing object will be supported further on).
Incompatibilities UVR1611 (A1.39 resp. A1.54):
- Parameterization => Adjustment if errors should be saved in Function control.
|
|
1.10
|
from A1.52 B1.01
|
29.04.04
|
New:
|
|
1.03
|
A1.38 B1.01
|
07.04.04
|
Modifications:
- Mandatory input variables of function objects are indicated colored.
New:
- Library object „Sensor status“ (Library: Inputs/Outputs)
- Library object “Message” (Library: Messages)
- Arranging of messages possible.
- Installation program creates folder „Projects“, with UVR1611 factory settings
|
|
1.02
|
A1.37 B1.01
|
23.02.04
|
Modifications:
- Bug-fix: Segmentation fault on starting of TAPPS
New:
- EDITOR for Function overview
- ARRANGE of functions possible
Incompatibilities UVR1611 version A1.36:
- Parameterization => Offset of input variables in Analog function
|
|
1.01
|
A1.35 B1.01
|
01.12.03
|
Modifications:
- Bug-fix on copying of already parameterized functions in drawing level.
|
|
1.00
|
A1.35 B1.01
|
26.11.03
|
- FIRST VERSION
|