Sensors
 |
PT1000/KTY
RASPT provides the possibility of changing the room Temperature in heating mode by approximately +/- 4°C and making the selection between the individual operating modes (normal, lowered or automatic mode or frost protection).
The room sensor is available as PT1000 (RASPT) und KTY (RAS) version. Temperature range: from 10°C to 40°C.
|
|
|
Read more... [Room sensor]
|
|

Air sensor with integrated overvoltage protection, for use as outdoor sensor or room sensor for heating controllers.
Art. Nr.: 01/AUS
|
|
Read more... [Outdoor sensor]
|
|
|
Temperature-resistant sensor with 2 m silicone cable for collector, supplied with connection box and overvoltage protector. KF: Standard, semiconductor characteristics, permanent use at up to 180 °C, chromed brass sensor cap, 6 x 20 mm. Art. no.: 01/KF
KFPT1000: Use at up to 240 °C for short periods, PT1000 characteristics, chromed brass sensor cap, 6 x 40 mm. Art. no.: 01/KFPT1000
KFPT1000 in 4x40 mm, Use at up to 240 °C for short periods
Art. Nr.: 01/KFPT10004x40MM
|
|
|
Read more... [Temperatursensor Kollektor]
|
|
|
Sensor with 2 m cable BF: Standard, semiconductor characteristics, up to 90 °C, chromed brass sensor cap, 6 x 20 mm. Art. no.: 01/BF BFPT1000: High accuracy with PT1000 characteristics, up to 180 °C, chromed brass sensor cap, 6 x 40 mm. Art. no.: 01/BFPT1000
BFPT1000 in 4x40mm Ausführung, up to 180 °C
Art.Nr.01/BFPT10004x40MM
|
|
|
Read more... [Storage tank temperature sensor]
|
|
|
Temperature-resistant sensor with 2 m silicone cable for use in boiler area, semiconductor characteristics, permanent use at up to 180 °C, chromed brass sensor cap, 6 x 20 mm.
Art. no.: 01/KE
|
|
|
Read more... [Boiler temperature sensor]
|
|
|
Brass installation kit + ultra-fast sensor for sanitary water heating. Brass screw connection, 1/2’’ male thread + ultra-fast sensor
Art. no.: 01/MSV+SSPT
|
|
|
There are no translations available.
 |
FTS2-32DL / FTS4-50DL / FTS5-85DL / FTS 9-150DL
Der elektronische Volumenstromsensor FTS basiert auf dem Prinzip der Karman‘schen Wirbelstraße. Ein in der Strömung stehender Staukörber erzeugt Wirbel. Diese werden durch ein piezoelektrisches Paddel detektiert und durch die integrierte Elektronik ausgewertet. Ein Mikroprozessor wandelt die analogen Messwerte in ein für den DL-Bus (Datenleitung) geeignetes serielles Digitalsignal um.
|
|
|
Read more... [Volumenstromsensor-HUBA]
|
 |
The electronic flow sensor VFS2-40 is based on the principle of Kármán vortex street. The frequency of the detached eddies of the flow below the flow body is in direct connection with the flow velocity.
A microprocessor records these oscillations and the temperature of the medium and creates a precise voltage.
Art. Nr.: 01/VFS1-12 Art. Nr.: 01/VFS2-40 Art. Nr.: 01/VFS5-100
|
|
|
Read more... [electronical flow sensor]
|
|

For exact flow metering The models VSG1,5 and VSG2,5 are single-jet water meters with one pulse per 0.5 litres, model VSG6,0 is a multiple-jet meter with one pulse per litre.
Art. no.: 01/VSG1,5 Art. no.: 01/VSG2,5 Art. no.: 01/VSG6,0 |
|
Read more... [Flow sensor]
|
|
The electronic pressure sensor RPS0-6 is based on the principle of a silicon membrane bending by the differential pressure. The changing ohmic resistance, in case of the bending, is measured in connection with the temperature, recorded by a microprocessor and converted into precise voltage.
Art. Nr.: 01/RPS0-6 |
|
Read more... [electronical pressure sensore]
|
|

Link between the sensors VFS1-20, VFS5-100 and VFS2-40 to the data line (DL-Bus).
Art. Nr.: 01/SGF-DL |
|
Read more... [Signal converters for VFS / RPS types]
|

|
The flow switch is used as a detector for sanitary water heating. It switches when the flow reaches approx. 1.5 litres/minute, has a permissible temperature range of up to +70 °C, a 1’’ male thread, and a 1’’ union. It must be fitted vertically, with flow from bottom to top. Art. no.: 01/STS01AC alternating current version 230 V AC / 1.5 A Art. no.: 01/STS01DC direct current version 30 V AC / 10 mA
|
|
|
Read more... [Flow switch]
|
|

For recording solar radiation in watts/m², accuracy ± 10%, facilitates system start-up and priority control in multiple-circuit systems.. A collector tracking system can be set up using two sensors. Measuring amplifier converts sensor signal into temperature (1000 W/m² = 100 °C).
Art. Nr.: 01/GBS01
|
|
Read more... [Radiation sensor]
|
|

For weather-dependent control tasks, e.g. opening and closing conservatory windows. Measuring amplifier converts sensor signal into temperature.
Art. no.: 01/RES01
|
|
Read more... [Rain sensor]
|
|

|
The humidity sensor was designed for controling tasks in the field of air conditioning in combination with UVR controls. The integrated microprocessor records the humidity and the temperature. Thus, the user can issue between the humidity or dew point selection. The circuit behaves as a temperature sensor at the controller. A separate supply is not required.
Art.Nr. 01/RFS
|
|
|
Read more... [Humidity Sensor]
|
 |
The differential pressure sensor DDS-DL is based on the principle of two silicon membranes rotated at 90° relative to each other so that they deflect under the differential pressure. The ohmic resistance which changes as a result of the deflection is captured as the measured variable. The displacement of the membranes relative to each other guarantees, even at the least pressure, position-independent signal accuracy. A microprocessor converts the differential pressure signal into a serial digital signal suitable for the DL-bus (data link).
Art.Nr.01/DDS-DL
|
|
|
Read more... [Differential pressure sensor]
|
|
Records temperatures at up to 600 °C. Measuring amplifier converts sensor signal into temperature (display value reduced by a factor of 10). Art. no.: 01/THEL
Measuring amplifier for thermocouple of type K (without thermocouple). Art. Nr.: 01/THEL-MV
|
|
|
Read more... [Thermo-element]
|
|

For wind speeds up to 140 km/h with a maximum deviation of 5%. Signal: pulse output at 1 Hz per 20 km/h. Diameter of installation: 30 mm. Note: because it does not have an integrated heating element, it is only of limited use for taking measurements in winter.
Art. no.: 01/WIS01
|
|
Read more... [Anemometer]
|
|
|
|