Due to its function modules, the UVR1611 unit can be freely programmed to suit any system configuration for heating space management. As each function module can be implemented many times over, it is also possible to realise complex control systems, such as solar thermal systems with several collector panels and tanks, or several weather-controlled heating circuits.
|
|
 |
CAN-Touch
The CAN-Touch is a 10“ LCD monitor with a touch-sensitive surface. It provides a display and operating interface for the freely programmable UVR1611 control.
|
|
| | Relay module for UVR1611 Expansion of the UVR1611K universal controller with 2 potential-free relay outputs (A12 & A13). Switching power max. 3 A per output. | |
 |
Pre-assembled starter and advanced packages for the UVR1611. |
|
|
|
For switchboard mounting. This board can be
custom fitted.
|
|
| | with 550 mm long connecting cables to the NM board. Together this two parts show a full UVR1611 with the usual controls visualization and BUS facilities. | |
|
|
Like UVR1611E-NM but with processor module as part of the controller without operating and visualization possibility. For visualization and operation in this combination the CAN monitor is planned.
|
|
| | Case for UVR1611E board includes mounting plate, spacer, Cable glands and grommets (without board).
Dimensions: 36x25, 5x11 cm
Art.Nr.: 01/UVR1611E-GH | |
|
|
The CAN monitor is a display and control unit for the freely programmable universal controller UVR1611, and simultaneously serves as a room sensor. The CAN-MT is responsible for the room temperature, and the model CAN-MT/F can also be used as a moisture sensor. It works according to the same operating concept as the UVR1611 controller, with communication via CAN bus. This makes it possible to set up a network with additional CAN monitors and several UVR1611 controllers. It is possible to access one controller from several CAN monitors, and to access several controllers in the network from one CAN monitor.
|
|
| | The CAN I/O module provides the freely programmable universal controller UVR1611 with additional inputs and outputs. The CAN bus is used for communication. The parameters of the CAN I/O module are set either via the CAN monitor, or via the UVR1611 controller. | |
| | The CAN-Busconverter provides additional interfaces for UVR1611. For communication, the CAN bus is used. - Standard CAN Bus Interface
- Second CAN Bus interface with selectable Busrate, optionally in fiber optics Execution
- EIB / KNX interface
- M-Bus interface
| |
 | CAN – energy meter The CAN-EZ energy meter is used for heat quantity counting and electrical energy metering. Simultaneously it calculates the coefficient of performance for heat pumps. Communication is via the CAN bus. | |
|
|
This device is a quad-signal converter with the different signal levels or current to voltage can be changed the other way around. In particular, it is meant to signal matching between UVR controls and external devices.
|
|
|
|
Development environment for programming and testing new function data. The EWS development kit contains a UVR1611K controller without console, a bootloader, a simulation board, and data cables for CAN bus and PC.
|
|
|
|
In conjunction with a UVR1611K controller, the SIM-BOARD is used for sensor simulation. Programming and data backups are possible via a CAN cable connection. Temperature simulation of all 16 inputs from -10 °C to 125 °C. In addition, inputs 15 and 16 can also be represented digitally.
|
|
  |
This console is for mounting the UVR1611K controller. The controller must be mounted on a at, clean and dry wall surface. The electrical connection is made in the console. Next the UVR1611K is inserted through the provided opening and connected to the wiring via contact pins.
Art.Nr: 01/KONSOLE UVR1611
|
|
|
|
Power supply unit is required for CAN bus when there are 3 or more bus participants without own power supply (e.g. CAN-MT, CAN-I/O, BL-NET)
|
|
|
|